21
7. Preset Button
Preset push button is used in conjunction with the VOLTAGE/CURRENT/TRIM knob to set the desired voltage / current. Pre-
set switch is also used in the Pulse Mig mode to preset the pulse parameters by using preset wire feed speed as the intial
setting for the “Off the Arc” feeder.
8. Standard / MIG Pulse Switch
This switch enables the Mig pulse mode. When this switch is in the MIG PULSE position, the pulse parameters are determined
by the WIRE TYPE and WIRE DIAMETER position on the PULSE SELECTION switches.
9. Pulse Selection Switches
WIRE TYPE
Use this switch to select the WIRE TYPE used by the wire feeder. The position of this switch and the WIRE DIAMETER switch
selects the pulse parameters to be used during welding in the Mig pulse mode.
WIRE DIAMETER
Use this switch to select the WIRE DIAMETER being used. The position of this switch and the WIRE TYPE switch selects the
pulse parameters during welding in the Mig pulse mode.
SECTION 2 DESCRIPTION