ESAB MultiPower 460 Pulse Manuál s instrukcemi Strana 23

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 52
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 22
23
Table 3-2. Output Cable Sizes (Secondary)
* Total cable length includes work and electrode cables. Cable size is based on direct
current, insulated copper conductors, 100-percent duty cycle and a voltage drop of 4 or
less volts. The welding cable insulator must have a voltage rating that is high enough to
withstand the open circuit voltage of the power source.
Welding
Current
Total Length (Feet) of
Cable in Weld Circuit*
50 100 150 200 250
100
150
200
250
300
400
500
6
4
3
2
1
2/0
3/0
4
3
1
1/0
2/0
3/0
3/0
3
1
1/0
2/0
3/0
4/0
4/0
2
1/0
2/0
3/0
4/0
4/0
2-2/0
1/0
2/0
3/0
4/0
4/0
2-2/0
2-3/0
Before making any connections to the
power source output terminals make
sure that all primary input power to the
machine is off.
INSTALLATION
D. OUTPUT WELDING CONNECTIONS
(SECONDARY)
The output connections are located on the front panel (Figure 2-5). The positive
connection is located at the bottom left corner and the negative connection is
located at the bottom right corner. Table 3-2 provides the recommended
secondary cable output sizes.
1. CONNECTIONS FROM THE WIRE FEEDER
The secondary output cable connects (in most cases) between the
positive output lug of the MultiPower 460 Pulse and the power
connection block of the wire feeder. See the wire feeder installation
instructions for other connections such as shield gas, water, remote
controls, Mig guns and wire feeder operation.
2. CONNECTIONS FOR STICK AND TIG WELDING
The Tig torch and stick electrode holder connect directly to the
appropriate MultiPower 460 Pulse output lugs on the lower front panel.
The choice of the Positive or Negative terminal depends on the welding
process and electrode type being used. In most cases the Tig torch
will connect to the negative lug and work cable will connect to the
positive lug. The stick electrode holder usually connects to the positive
lug and the work cable to the negative lug.