20
1. The primary power leads must be insulated copper conductors. Three
power leads and one ground wire are required. Either rubber covered
cable or conduit (flexible or solid) may be used. Table 3-1 provides
recommended input conductors and line fuse sizes.
ELECTRIC SHOCK CAN KILL! Before
making electrical input connections
to the power source, "Machinery
Lockout Procedures" should be em-
ployed. If the connections are to be
made from a line disconnect switch,
place the switch in the off position
and padlock it to prevent inadvert-
ent tripping. If the connection is
made from a fuse box, remove the
corresponding fuses and padlock
the box cover. If it is not possible to
use padlocks, attach a red tag to the
line disconnect switch (or fuse box)
warning others that the circuit is
being worked on.
The chassis must be connected to
an approved electrical ground. Fail-
ure to do so may result in electrical
shock, severe burns or death.
Typical Installation - User Supplied
3 Phase Fused Power Disconnect
Box with Receptacle and Plug
INSTALLATION
SECTION 3
REAR PANEL VIEW