ESAB MultiPower 460 Pulse Manuál s instrukcemi

Procházejte online nebo si stáhněte Manuál s instrukcemi pro Svařovací systém ESAB MultiPower 460 Pulse. ESAB MultiPower 460 Pulse Instruction manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 52
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
0558003754 03 / 2006
MultiPower
460 Pulse
DC WELDING POWER SOURCE
(Shipyard Model)
INSTRUCTION MANUAL
ESAB ITEM NO. 0558003402, MultiPower 460 Pulse - 230/460/575 vac, 3 ph., 60 Hz
Serial Number: Mxxx333xxx
Zobrazit stránku 0
1 2 3 4 5 6 ... 51 52

Shrnutí obsahu

Strany 1 - 460 Pulse

0558003754 03 / 2006MultiPower 460 PulseDC WELDING POWER SOURCE(Shipyard Model)INSTRUCTION MANUALESAB ITEM NO. 0558003402, MultiPower 460 Pulse - 230

Strany 2 - USER RESPONSIBILITY

10levage, des câbles de grue ou divers cheminsélectriques.g. Empêchez l’apparition de toute humidité, notammentsur vos vêtements, à la surface de l’em

Strany 3 - TABLE OF CONTENTS

11Table 2-1. Specifications for MultiPower 460 Pulse2.1. SAFETYBefore the MultiPower 460 Pulse power source is put into operation, thesafety section a

Strany 4

12The MultiPower 460 Pulse is a multi-process power source designed for Migshort circuiting, spray and pulse spray transfer (GMAW), flux core (FCAW),T

Strany 5 - SECTION 1 SAFETY PRECAUTIONS

13Figure 2-3. Pulse Control PanelSECTION 2 DESCRIPTIONC. CONTROL PANEL DESCRIPTION (Refer to Figures 2-3 and 2-4)1. FAULT LAMP The RED fault lig

Strany 6

14DESCRIPTIONSECTION 2When using a DuraDrive 4-30 or DuraDrive 4-48 Wire Feeder, the wire feedspeed is displayed in inches per minute (IPM) in the top

Strany 7

15Figure 2-5. MultiPower 4607. INDUCTANCE TRIMThis control is used only in the STANDARD mode and is deactivated in theTIG, STICK and PULSE modes. In

Strany 8 - §25249.5 et seq.)

16DESCRIPTIONSECTION 21. POWER ON/OFF SWITCH & LAMPThe main power switch is located on the right front panel of the power source.This switch ener

Strany 9

17Figure 2-6. Remote Control PendantDESCRIPTIONSECTION 2NOTEIf a Remote Control Pendant is used forcontinuous current control, place thePANEL/REMOTE s

Strany 10

18DESCRIPTIONSECTION 2

Strany 11 - DESCRIPTION

19Table 3-1. Recommended Sizes for InputConductors and Line Fuses*Sized per National Code for 80 °C rated copper conductors @ 30 °C ambient. Not more

Strany 12

2These INSTRUCTIONS are for experienced operators. If you are not fully familiar with the principlesof operation and safe practices for arc welding a

Strany 13 - SECTION 2 DESCRIPTION

201. The primary power leads must be insulated copper conductors. Threepower leads and one ground wire are required. Either rubber coveredcable or co

Strany 14

212. Remove the top cover. Identify primary power input connection block,chassis ground lug on the fan shroud frame, and primary input terminalboard.

Strany 15

22Check the voltage links for proper volt-age on the Input Terminal board beforeapplying primary power.5. Figure 3-3 illustrates the input voltage ter

Strany 16

23Table 3-2. Output Cable Sizes (Secondary)* Total cable length includes work and electrode cables. Cable size is based on directcurrent, insulated c

Strany 17

24INSTALLATIONSECTION 3

Strany 18

25SECTION 4OPERATION4.1. OPERATIONA. WIRE FEEDER COMPATIBILITYThe MultiPower 460 Pulse power source can be used with several types of wirefeeders. T

Strany 19 - SECTION 3

26NOTEIf a Remote Hand Control is used for con-tinuous current control, place the PANEL/REMOTE switch in the PANEL POSITIONand set the Panel Current k

Strany 20

27SECTION 4OPERATIOND. STICK WELDINGWhen the PROCESS switch is placed in the STICK position, the MultiPower 460Pulse establishes open circuit voltage

Strany 21

28When the WELD PROCESS switch ismoved to the TIG or STICK position,electrode becomes electrically “HOT”.Do not allow the electrode to contactground p

Strany 22

29SECTION 4OPERATIONF. MIG & FLUX CORE WELDING PRESET PROCEDUREWhen the PROCESS switch is placed in the MIG position, the MultiPower 460Pulse is

Strany 23

3TABLE OF CONTENTSSECTION TITLE PAGESECTION 1 SAFETY ...

Strany 24 - INSTALLATIONSECTION 3

30Table 4-2 Wire Types, Diameter and Shield GasesSECTION 4OPERATIONMaterial Type DiametersShielding Gas (AWS Designation)Carbon

Strany 25 - OPERATION

31SECTION 4OPERATIONFigure 4-6 Synergic Pulse MIG Setup32514The TRIM Knob on the front panel (Voltage knob) allows the operator to fine tunethe puls

Strany 26 - SECTION 4 OPERATION

32SECTION 4OPERATIONStep 6. Set the shielding gas flow rate to 35 cfh by activating the gas purgeswitch on the wire feeder or pulling the gun trigger

Strany 27

33SECTION 4OPERATION3. SHIELDING GASESTable 4-2 lists the types of shielding gas mixtures that can be used with theMultiPower 460 Pulse. The wire b

Strany 28

34SECTION 4OPERATIONJumper Plug Removed and Harness connected (as factory shipped)Non-Synergic Mode - The pulse parameters are determined by the posit

Strany 29

35SECTION 5MAINTENANCEThese circuits are protected by two 10 amp circuit breakers mounted in the frontpanel. If these open, the contactor and wire fe

Strany 30

36gCONDITION ACTIONUnit Inoperative A.B.C.D.E.No input power. Check main line (user's) switch fuses -- replace if needed.Poor or improper input

Strany 31

37Schematic Diagram Section 1 - MultiPower 460 - 230/460/575V0558003034-C

Strany 32

38Schematic Diagram Section 2 - MultiPower 460 - 230/460/575V0558003034-C

Strany 33

39Schematic Diagram Section 3 - MultiPower 460 - 230/460/575V0558003034-C

Strany 34

4TABLE OF CONTENTS

Strany 35 - MAINTENANCE

40Wiring Diagram Section 1 - MultiPower 460 - 230/460/575V0558003064-D

Strany 36

41Wiring Diagram Section 2 - MultiPower 460 - 230/460/575V0558003064-D

Strany 37 - 0558003034-C

42Wiring Diagram Section 3 - MultiPower 460 - 230/460/575V0558003064-D

Strany 38

43SECTION 6 REPLACEMENT PARTS6.1. REPLACEMENT PARTSReplacement Parts are illustrated on the following figures. When ordering replacement parts, order

Strany 39

44SECTION 6 REPLACEMENT PARTS1234, 56798QTY. ITEM CIRCUITNO. REQ. NO. DESCRIPTION SYMBOL0558003402 MultiPower 460 Pulse (Shipyard Model)1 2 678025 Ter

Strany 40 - 0558003064-D

45SECTION 6 REPLACEMENT PARTSQTY. ITEM CIRCUITNO. REQ. NO. DESCRIPTION SYMBOL0558003402 MultiPower 460 Pulse (Shipyard Model)1 2 678025 Terminal Asse

Strany 41

46SECTION 6 REPLACEMENT PARTS621QTY. ITEM CIRCUITNO. REQ. NO. DESCRIPTION SYMBOL0558003402 MultiPower 460 Pulse (Shipyard Model)1 0558004100 Kit, Puls

Strany 42

4712345SECTION 6 REPLACEMENT PARTSQTY. ITEM CIRCUITNO. REQ. NO. DESCRIPTION SYMBOL0558003402 MultiPower 460 Pulse (Shipyard Model)1 1 1312733 Label fo

Strany 43 - SECTION 6 REPLACEMENT PARTS

48SECTION 6 REPLACEMENT PARTSQTY. ITEMNO. REQ. NO. DESCRIPTION SYMBOL0558003402 MultiPower 460 Pulse (Shipyard Model)1 3 99511916 Diode Fwd 200V 250A2

Strany 44

491234SECTION 6 REPLACEMENT PARTSQTY. ITEMNO. REQ. NO. DESCRIPTION SYMBOL0558003402 MultiPower 460 Pulse (Shipyard Model)1 2 17280110 Res WW Fix'

Strany 45

5WARNING: T hese Safety Precautions are foryour protection. They summarize precaution-ary information from the references listed inAdditional Safety I

Strany 46

5012543SECTION 6 REPLACEMENT PARTSQTY. ITEMNO. REQ. NO. DESCRIPTION SYMBOL0558003402 MultiPower 460 Pulse (Shipyard Model)1 1 952938 SCR 480V 18A Pane

Strany 47

51REVISION HISTORY1. 07 / 2003 - "A" REVISION - Updated all front panel diagrams to show new layout, also updated front paneldiagram in repl

Strany 48

IF YOU DO NOT KNOW WHOM TO CALLTelephone: (800) ESAB-123/ Fax: (843) 664-4452/ Web:http://www.esab.comHours: 7:30 AM to 5:00 PM ESTA. CUSTOMER SERVICE

Strany 49

6FUMES AND GASES -- Fumes andgases, can cause discomfort or harm,particularly in confined spaces. Donot breathe fumes and gases. Shield-ing gases can

Strany 50

7ADVERTENCIA: Estas Precauciones de Seguridadson para su protección. Ellas hacen resumen deinformación proveniente de las referencias listadasen la s

Strany 51 - REVISION HISTORY

8HUMO Y GASES -- El humo y los gases,pueden causar malestar o daño,particularmente en espacios sinventilación. No inhale el humo o gases. Elgas de

Strany 52 - 0558003754 03 / 2006

9coupes à l’arc, à moins de les recouvrir complètementd’une bâche non-inflammable. Ce type de matériauxcomprend notamment le bois, les vêtements, la s

Komentáře k této Příručce

Žádné komentáře