4.0. OPERATION
A. WIRE FEEDER COMPATIBILITY
The Multipower 460PULSE power source can be used with several ESAB 42 volt
wire feeders. The model wire feeder being used will determine the setup method
and operator interface. The position of the REMOTE/PANEL switch determines
the location of the voltage preset and TRIM locations. The wire feed speed is
always set from the wire feeder using the wire speed knob on the feeder control
Table 4-1. Wire Feeder Compatibility
panel. To see the preset wire feed speed, press the PRESET button on the
Multipower 460PULSE control panel. Use Table 4-1 to determine the switch
position of operator preference. In most Mig welding applications, the switch will
be in the REMOTE position and the wire feed speed and voltage will be adjusted
from the wire feed front panel.
B. DIGITAL DISPLAY METERS
The digital displays located on the left side of the control panel are multifunctional
depending on the welding process being used. The Multipower 460PULSE digital
display meters permit preset of the wire feed speed on wire feeders without digital
displays. A Mig 2E, 4HD or DuraDrive 4-30 or 4-48 will not need digital meters
to preset the wire feed speed. The wire feed speed can be displayed on the
Multipower 460PULSE panel meter.
C. MIG WELDING
In the MIG process mode, the digital displays will read preset wire feed speed
in inches per minute and preset arc volts when the PRESET button is pressed.
Once welding begins, the displays will show average welding current and volts
in the top and bottom display, respectively. The displays have a “HOLD” circuit
that retains the welding conditions. After welding stops, the display will continue
to show the last average welding current and voltage sampled for 10 seconds,
then returns to “0”.
D. TIG and STICK WELDING
In the TIG and STICK process mode, you must depress and "HOLD" the
PRESET button while presetting the welding current in the top display. Releas-
ing the preset button causes the display to return to zero. Once welding begins,
Never operate the power source with
the covers removed. In addition to the
safety hazards, improper cooling may
cause damage to the components.
Keep side panels and top closed when
unit is energized. Welding helmet,
gloves, and other personal protection
should always be worn when welding.
NOTE
Wire Feeders with 115VAC contactor
control circuitry cannot be connected to
the Multipower 460.
NOTE
The digital wire feed speed meter on the
Multipower front panel reads a maximum
of 760 ipm. Some wire feeders have
speed ranges that exceed this maximum
limit of the digital meter. Wire feed speeds
above 760 ipm will be displayed at 760
ipm.
NOTE
The digital volt meter on the Multipower
front panel reads a maximum of approxi-
mately 75 Vdc even if the OCV (Open
Circuit Voltage) is higher. The Multipower
460 has the following OCV"s:
STICK 75 to 80 Vdc
TIG - 38 to 42 Vdc
MIG - 11 to 44 Vdc
(Applies to Multipower 460PULSE only)
SECTION 4 OPERATION
Wire Feeder
Arc Trim Location
from:
PANEL REMOTE Synergic
Non-
Synergic**
Mig 4HD
DuraDrive 4-30 Feeder X X Optional
DuraDrive 4-48
MP-460 Panel X X Optional
Mig 2E Feeder X N/A
Mig 5XL
(Mongoose)
Remote Pendant X X Optional
MP-460 Panel X X Optional
MobileMaster IV
(Off the Arc)
Feeder X N/A N/A X
Mini 8
(Off the Arc)
Remote Pendant X N/A X
MP-460 Panel X N/A X
N/A - Not Available
* - Process switch MUST be in the MIG position.
** - See Synergic/NonSynergic description section for configuration information
STANDARD
(MultiPower 460)
PULSE
(MultiPower 460 Pulse)
MIG MODE SWITCH*
NOTE
Wire Feeders with remote voltage control
must be disconnected before Tig & Stick
current can be controlled by the remote
control pendant.