3 TECHNICAL DATA
Tig 3001i
Mains voltage 400 V $10%, 3 50/60 Hz
Mains supply S
sc
min
1.4 MVA
Primary current
I
max
TIG
I
max
MMA
13 A
19 A
No-load power demand when in the
energy-saving mode, 6.5 min. after welding
30 W
Setting range
TIG
MMA
4 - 300 A
16 - 300 A
Permissible load at TIG
35 % duty cycle
60% duty cycle
100% duty cycle
300 A / 22 V
240 A / 19.6 V
200 A / 18 V
Permissible load at MMA
30 % duty cycle
60% duty cycle
100% duty cycle
300A / 32 V
230 A / 29.2 V
190 A / 27.6 V
Power factor at maximum current
TIG
MMA
0.9
0.89
Efficiency at maximum current
TIG
MMA
81 %
84 %
Open-circuit voltage U
0
max
without VRD function
1)
U
0L
“Live TIG”, VRD function deactivated
2)
MMA, VRD function deactivated
2)
VRD function activated
2)
67 V
60 V
60 V
<35 V
Operating temperature -10 to +40° C
Transportation temperature - 20 to +55° C
Constant sound pressure at no-load < 70 dB (A)
Dimensions lxwxh
with cooling unit
652 X 249 X 423 mm
714 X 249 X 693 mm
Weight
with cooling unit
33.5 kg
54 kg
Insulation class transformer H
Enclosure class IP 23
Application class
1) Valid for power sources without VRD specification on the rating plate.
2) Valid for power sources with VRD specification on the rating plate.The VRD function is explained in
the instructions for the control panel, if the panel has that function.
Mains supply, S
sc
min
Minimum short circuit power on the network in accordance with IEC 61000-3-12